Intraocular lens power calculations in eyes with pseudoexfoliation syndrome

Intraocular lens power calculations in eyes with pseudoexfoliation syndrome Đăng ngày 14-11-2024

Abstract

To compare refractive outcomes after cataract surgery in pseudoexfoliation syndrome (PEX) and control eyes and to investigate the accuracy of 3 intraocular lens (IOL) calculation formulas in these eyes. In this prospective comparative study 42 eyes (PEX group) and 38 eyes (control group) of 80 patients were included. The follow-up was 3 months. The refractive prediction error (RPE), mean absolute error (MAE), median absolute error (MedAE) and the percentages of eyes within ± 0.25 D, ± 0.5 D, ± 1.0 D and ± 2.0 D of prediction error were calculated. Three IOL calculation formulas (SRK/T, Barrett Universal II and Hill-RBF) were evaluated. PEX produced statistically significantly higher mean absolute errors and lower percentages of eyes within ± 0.5 D than control eyes in all investigated IOL calculation formulas. There were no statistically significant differences in the median absolute errors between the 3 formulas in either PEX or control eyes. Refractive outcomes after cataract surgery are statistically significantly worse in PEX than in control eyes. All three IOL calculation formulas produced similar results in both PEX and control eyes.Trial registration: ClinicalTrials.gov registration number